BWIPP minimal encoding by Bue Jensen (BWIPP PR #278);
new extra escape `\^@` to turn off manual switching
zint.h: increase `symbol->text` size 200 -> 256 (means that for
the moment can no longer generate ZINT_WARN_HRT_TRUNCATED)
GS1_128/GS1_128_CC: warn if READER_INIT option used
CODE16K: move `c16k_set_a/b/c()` routines from "code128.c" and
rename `c16k_` (also `C128_` defines to `C16K_`)
common: make `itoc()` simple macro which adds '0' (>= 10 now ':',
';' etc) and adjust `expand()` accordingly for slight speed-up
general: EXTRA_ESCAPE_MODE now implies ESCAPE_MODE
tests: update BWIPP to latest and enable CODE128AB ("suppressc");
new test args '-n' (exclude func) and '-m' (match func)
EMF/PCX/PNG/TIF only, i.e. excluding EPS, GIF & SVG)
- Add support for specifying scale by X-dimension and resolution
with new option `--scalexdimdp` for CLI/Tcl & new API function
`ZBarcode_Scale_From_XdimDp()` (+ `ZBarcode_XdimDp_From_Scale()`
& `ZBarcode_Default_Xdim()`) and new GUI popup; manual: document
- BMP/EMF/PCX/PNG/TIF: use new `dpmm` resolution field (for EMF
following Inkscape)
- backend_qt: add `dpmm()`, `vectorWidth()`, `vectorHeight()`,
`noPng()`, `getVersion()`, `takesGS1AIData()`, & `XdimDp` stuff
incl. new `QZintXdimDp` struct for passing around scale vars &
use in `getAsCLI()`; add comments
- Raise `scale` limit to 200 (from 100) to allow for large dpmm
- output: create directories & subdirectories as necessary for
output path using new function `out_fopen()` and use in BMP/EMF/
EPS/GIF/PCX/PNG/SVG/TIF
- DPLEIT/DPIDENT: format HRT according to (incomplete)
documentation, and set default height to 72X (from 50X)
- CODE128B renamed to CODE128AB as can use subsets A and/or B
- CODABAR: fix minimum height calc
- EMF: fix indexing of handles (zero-based not 1-based)
- GUI: fix symbology zap (previous technique of clearing and
re-loading settings without doing a sync no longer works);
fix UPCEAN guard descent enable
- MAILMARK: better error message if input < 14 characters
- GUI: add "Default" button for DAFT tracker ratio & enable/disable
various default buttons; use new `takesGS1AIData()` to
enable/disable GS1-specific checkboxes
- CLI: use new `validate_float()` to parse float options (7
significant digits allowed only, no scientific notation)
- DATAMATRIX/GRIDMATRIX/PDF417/QR/ULTRA: micro-optimize structapp
ID parse
- library/CLI: fiddle with static asserts (make CHAR_BIT sensitive,
supposedly)
- win32/README: update building libpng (assembly removed)
- README.linux: document incompatibility of Qt6 >= 6.3
- manual: expand Barcode Studio waffle
- test suite: change range separator to hyphen and allow multiple
excludes
The ```configuration``` is required by the visual studio generator to determine
whether to use a Debug or a Release setup (or a user customized one). It's
required by whatever uses that generator rather then just the GUI code.
Add instructions for the Visual Studio Project File generator to the README
and enable the test on Windows.
PLESSEY: add options NCR weighted mod-10, hide check digit(s) in HRT
test suite: now runnable under MSVC 2019, 2017, 2015, MinGW/MSYS
win32/README: update with MSVC 2019 and CMake instructions