mirror of
https://git.code.sf.net/p/zint/code
synced 2025-12-17 09:57:02 +00:00
- GS1: fix square brackets treated as FNC1 in GS1PARENS_MODE by
changing internal FNC1 marker '[' -> '\x1D' (GS), ticket #319, props Moli Sojet; also fix non-AI square brackets -> round brackets in GS1_128 HRT - BWIPP: update to latest
This commit is contained in:
@@ -4027,7 +4027,10 @@ usage is given in section <a href="#gs1-128">6.1.10.3 GS1-128</a>.</p>
|
||||
data that does not conform to the current GS1 standard. Printable ASCII
|
||||
input is still checked for, as is the validity of GS1 data specified
|
||||
without AIs (e.g. linear data for GS1 DataBar
|
||||
Omnidirectional/Limited/etc.).</p>
|
||||
Omnidirectional/Limited/etc.). Also checked is GS1 DataBar Expanded and
|
||||
GS1 Composite input that is not in the GS1 encodable character set 82
|
||||
(see GS1 General Specifications Figure 7.11.1 ‘GS1 AI encodable
|
||||
character set 82’), otherwise encodation would fail.</p>
|
||||
<p>For <code>HEIGHTPERROW_MODE</code>, see <code>--heightperrow</code>
|
||||
in section <a href="#adjusting-height">4.4 Adjusting Height</a>. The
|
||||
<code>height</code> member should be set to the desired per-row value on
|
||||
|
||||
@@ -2406,7 +2406,10 @@ example of `GS1PARENS_MODE` usage is given in section [6.1.10.3 GS1-128].
|
||||
`GS1NOCHECK_MODE` is for use with legacy systems that have data that does not
|
||||
conform to the current GS1 standard. Printable ASCII input is still checked for,
|
||||
as is the validity of GS1 data specified without AIs (e.g. linear data for GS1
|
||||
DataBar Omnidirectional/Limited/etc.).
|
||||
DataBar Omnidirectional/Limited/etc.). Also checked is GS1 DataBar Expanded and
|
||||
GS1 Composite input that is not in the GS1 encodable character set 82 (see GS1
|
||||
General Specifications Figure 7.11.1 'GS1 AI encodable character set 82'),
|
||||
otherwise encodation would fail.
|
||||
|
||||
For `HEIGHTPERROW_MODE`, see `--heightperrow` in section [4.4 Adjusting Height].
|
||||
The `height` member should be set to the desired per-row value on input (it will
|
||||
|
||||
@@ -2379,7 +2379,10 @@ GS1PARENS_MODE usage is given in section 6.1.10.3 GS1-128.
|
||||
GS1NOCHECK_MODE is for use with legacy systems that have data that does not
|
||||
conform to the current GS1 standard. Printable ASCII input is still checked for,
|
||||
as is the validity of GS1 data specified without AIs (e.g. linear data for GS1
|
||||
DataBar Omnidirectional/Limited/etc.).
|
||||
DataBar Omnidirectional/Limited/etc.). Also checked is GS1 DataBar Expanded and
|
||||
GS1 Composite input that is not in the GS1 encodable character set 82 (see GS1
|
||||
General Specifications Figure 7.11.1 ‘GS1 AI encodable character set 82’),
|
||||
otherwise encodation would fail.
|
||||
|
||||
For HEIGHTPERROW_MODE, see --heightperrow in section 4.4 Adjusting Height. The
|
||||
height member should be set to the desired per-row value on input (it will be
|
||||
|
||||
Reference in New Issue