mirror of
https://git.code.sf.net/p/zint/code
synced 2026-01-25 12:55:59 +00:00
backend_tcl: add "win/readme.txt"; fiddle with "readme.txt"
README: copyright 2024 -> 2025; remove primarily Linux bit manual: update Tcl instructions; copyright 2024 -> 2025; Data Matrix ECC200 -> ECC 200, mention previous standards by name; manual/GUI: Pharmacode -> Pharmacode One-Track, 2-track Pharmacode -> Pharmacode Two-Track backend/DEVELOPER: update
This commit is contained in:
@@ -107,7 +107,7 @@ January 2025
|
||||
- 6.1.7.7 HIBC Code 39
|
||||
- 6.1.7.8 Vehicle Identification Number (VIN)
|
||||
- 6.1.8 Codabar (EN 798)
|
||||
- 6.1.9 Pharmacode
|
||||
- 6.1.9 Pharmacode One-Track
|
||||
- 6.1.10 Code 128
|
||||
- 6.1.10.1 Standard Code 128 (ISO 15417)
|
||||
- 6.1.10.2 Code 128 Suppress Code Set C (Code Sets A and B only)
|
||||
@@ -141,7 +141,7 @@ January 2025
|
||||
- 6.3.2 CC-B
|
||||
- 6.3.3 CC-C
|
||||
- 6.4 Two-Track Symbols
|
||||
- 6.4.1 Two-Track Pharmacode
|
||||
- 6.4.1 Pharmacode Two-Track
|
||||
- 6.4.2 POSTNET
|
||||
- 6.4.3 PLANET
|
||||
- 6.4.4 Brazilian CEPNet
|
||||
@@ -885,7 +885,7 @@ underscores are optional.
|
||||
|
||||
70 BARCODE_RM4SCC Royal Mail 4-State Customer Code (RM4SCC)
|
||||
|
||||
71 BARCODE_DATAMATRIX Data Matrix (ECC200)
|
||||
71 BARCODE_DATAMATRIX Data Matrix (ECC 200)
|
||||
|
||||
72 BARCODE_EAN14 EAN-14
|
||||
|
||||
@@ -931,7 +931,7 @@ underscores are optional.
|
||||
|
||||
99 BARCODE_HIBC_39 HIBC Code 39
|
||||
|
||||
102 BARCODE_HIBC_DM HIBC Data Matrix ECC200
|
||||
102 BARCODE_HIBC_DM HIBC Data Matrix
|
||||
|
||||
104 BARCODE_HIBC_QR HIBC QR Code
|
||||
|
||||
@@ -2997,11 +2997,11 @@ plus (+). No check character is generated by default, but a modulo-16 one can be
|
||||
added by setting --vers=1 (API option_2 = 1). To have the check character appear
|
||||
in the Human Readable Text, set --vers=2 (API option_2 = 2).
|
||||
|
||||
6.1.9 Pharmacode
|
||||
6.1.9 Pharmacode One-Track
|
||||
|
||||
[zint -b PHARMA --compliantheight -d "130170"]
|
||||
|
||||
Developed by Laetus, Pharmacode is used for the identification of
|
||||
Developed by Laetus, Pharmacode One-Track is used for the identification of
|
||||
pharmaceuticals. The symbology is able to encode whole numbers between 3 and
|
||||
131070.
|
||||
|
||||
@@ -3545,13 +3545,14 @@ string of shorter length. To select CC-C use --mode=3 (API option_1 = 3).
|
||||
|
||||
6.4 Two-Track Symbols
|
||||
|
||||
6.4.1 Two-Track Pharmacode
|
||||
6.4.1 Pharmacode Two-Track
|
||||
|
||||
[zint -b PHARMA_TWO --compliantheight -d "29876543"]
|
||||
|
||||
Developed by Laetus, Pharmacode Two-Track is an alternative system to Pharmacode
|
||||
One-Track (see 6.1.9 Pharmacode) used for the identification of pharmaceuticals.
|
||||
The symbology is able to encode whole numbers between 4 and 64570080.
|
||||
One-Track (see 6.1.9 Pharmacode One-Track) used for the identification of
|
||||
pharmaceuticals. The symbology is able to encode whole numbers between 4 and
|
||||
64570080.
|
||||
|
||||
6.4.2 POSTNET
|
||||
|
||||
@@ -3789,8 +3790,8 @@ default but also supports encoding in other character sets using the ECI
|
||||
mechanism. It can also encode GS1 data. The size of the generated symbol can be
|
||||
adjusted using the --vers option (API option_2) as shown in the table below. A
|
||||
separate symbology ID (BARCODE_HIBC_DM) can be used to encode Health Industry
|
||||
Barcode (HIBC) data. Note that only ECC200 encoding is supported, the older
|
||||
standards have now been removed from Zint.
|
||||
Barcode (HIBC) data. Note that only ECC 200 symbols are supported, the older
|
||||
standards (ECC 000 to 140) have now been removed from Zint.
|
||||
|
||||
Input Symbol Size Input Symbol Size Input Symbol Size
|
||||
------- ------------- -- ------- ------------- -- ------- -------------
|
||||
@@ -4571,7 +4572,7 @@ maximum of 128 digits and does not include a check digit.
|
||||
|
||||
7.1 License
|
||||
|
||||
Zint, libzint and Zint Barcode Studio are Copyright © 2024 Robin Stuart. All
|
||||
Zint, libzint and Zint Barcode Studio are Copyright © 2025 Robin Stuart. All
|
||||
historical versions are distributed under the GNU General Public License version
|
||||
3 or later. Versions 2.5 and later are released under a dual license: the
|
||||
encoding library is released under the BSD (3 clause) license whereas the GUI,
|
||||
@@ -4647,7 +4648,7 @@ international standards:
|
||||
|
||||
7.5.1 Symbology Standards
|
||||
|
||||
- ISO/IEC 24778:2008 Information technology - Automatic identification and
|
||||
- ISO/IEC 24778:2024 Information technology - Automatic identification and
|
||||
data capture techniques - Aztec Code bar code symbology specification
|
||||
- SEMI T1-95 Specification for Back Surface Bar Code Marking of Silicon Wafers
|
||||
(BC412) (1996)
|
||||
@@ -4662,9 +4663,8 @@ international standards:
|
||||
- ANSI/AIM BC6-2000 - Uniform Symbology Specification Code 49
|
||||
- ANSI/AIM BC5-1995 - Uniform Symbology Specification Code 93
|
||||
- AIM Uniform Symbology Specification Code One (1994)
|
||||
- ISO/IEC 16022:2006 Information technology - Automatic identification and
|
||||
data capture techniques - Data Matrix ECC200 bar code symbology
|
||||
specification
|
||||
- ISO/IEC 16022:2024 Information technology - Automatic identification and
|
||||
data capture techniques - Data Matrix bar code symbology specification
|
||||
- ISO/IEC 21471:2020 Information technology - Automatic identification and
|
||||
data capture techniques - Extended rectangular data matrix (DMRE) bar code
|
||||
symbology specification
|
||||
@@ -4830,10 +4830,10 @@ A Tcl binding is available in the "backend_tcl” sub-directory. To make on Unix
|
||||
make
|
||||
sudo make install
|
||||
|
||||
For Windows, a Visual Studio 6.0 project file is available at
|
||||
"backend_tcl\zint_tcl.dsp". This can also be opened (and converted) by more
|
||||
modern Visual Studio versions, though some fixing up of the project
|
||||
configuration will likely be required.
|
||||
For Windows, a Microsoft Visual C++ project file is available at
|
||||
"backend_tcl\zint_tcl.vcxproj". There is also a Visual Studio makefile available
|
||||
at "backend_tcl\win\makefile.vc", which can be run with nmake - for details see
|
||||
"backend_tcl\win\README.txt".
|
||||
|
||||
Once built and installed, invoke the Tcl/Tk CLI "wish":
|
||||
|
||||
@@ -5552,9 +5552,9 @@ CONFORMING TO
|
||||
Zint is designed to be compliant with a number of international standards,
|
||||
including:
|
||||
|
||||
ISO/IEC 24778:2008, ANSI/AIM BC12-1998, EN 798:1996, AIM ISS-X-24 (1995),
|
||||
ISO/IEC 24778:2024, ANSI/AIM BC12-1998, EN 798:1996, AIM ISS-X-24 (1995),
|
||||
ISO/IEC 15417:2007, EN 12323:2005, ISO/IEC 16388:2007, ANSI/AIM BC6-2000,
|
||||
ANSI/AIM BC5-1995, AIM USS Code One (1994), ISO/IEC 16022:2006, ISO/IEC
|
||||
ANSI/AIM BC5-1995, AIM USS Code One (1994), ISO/IEC 16022:2024, ISO/IEC
|
||||
21471:2019, ISO/IEC 15420:2009, AIMD014 (v 1.63) (2008), ISO/IEC 24723:2010,
|
||||
ISO/IEC 24724:2011, ISO/IEC 20830:2021, ISO/IEC 16390:2007, ISO/IEC 16023:2000,
|
||||
ISO/IEC 24728:2006, ISO/IEC 15438:2015, ISO/IEC 18004:2015, ISO/IEC 23941:2022,
|
||||
@@ -5562,7 +5562,7 @@ AIM ITS/04-023 (2022)
|
||||
|
||||
COPYRIGHT
|
||||
|
||||
Copyright © 2024 Robin Stuart. Released under GNU GPL 3.0 or later.
|
||||
Copyright © 2025 Robin Stuart. Released under GNU GPL 3.0 or later.
|
||||
|
||||
AUTHOR
|
||||
|
||||
|
||||
Reference in New Issue
Block a user